AMP 2026 · SEATTLE · BOOTH #915

Revolution Pro launches at AMP 2026.

Liquid biopsy extraction.
Built for automation.

Meet Revolution Pro and explore fully automated processing with the Revolution ES accessory. Bring your assay goals and laboratory workflow questions to our team at Booth #915.

Plan your visit to Booth #915
Revolution Pro with the Revolution Elution Station accessory
Revolution Pro/ESFully automated processing through wash and elution
ANNUAL MEETING & EXPONovember 10–14, 2026
LOCATIONSeattle Convention Center
VISIT NRICHDXBooth #915
SCIENTIFIC PROGRAM1 oral talk · 2 posters
THE REVOLUTION PRO LAUNCH

Your sample. Your assay. Your workflow.

The molecular input your assay needs.
The workflow your laboratory needs.

Developing an early-detection assay or running a production laboratory? Explore sample-input flexibility, molecular recovery, and automation options that fit the work you do.

Make your AMP visit count.

Discuss your sample types, target analytes, and daily processing needs with the people behind the Revolution platform.

Visit nRichDX at AMP 2026 in Seattle, Booth 915
Explore Revolution Pro at Booth #915
REVOLUTION PRO AT A GLANCEView specifications
80%–95%Extraction efficiency
1–100 mLSingle-extraction range*
24Samples per batch
10 minHands-on time per batch

* Up to 50 mL for cell-free applications.

AMP 2026 SCIENTIFIC PROGRAM

Meet the scientists. Explore the data.

Two studies. Three opportunities to connect. Join Nafiseh Jafari for an oral presentation and poster on automated cfDNA preparation, and Mayer Saidian for the nRichDX + GT Molecular poster.

All presentation times are Pacific Time.

POSTER PRESENTATIONG048

Scalable Plasma ctDNA Extraction Paired with Digital PCR for Ultra-Sensitive Detection of Low-Frequency Clinical Variants

Mayer Saidian
Mayer SaidianVP of R&D, nRichDX

A collaboration between nRichDX and GT Molecular.

Poster G048Friday, November 13
Continue the conversation at Booth #915.

Bring your questions about sample input, extraction, and downstream analysis.

Request time with our team
THE REVOLUTION PLATFORM AT AMP

Choose the automation your workflow needs.

Revolution Pro supports cfDNA, cfRNA, and cfTNA extraction with the appropriate reagents and protocol. Explore two configurations for the steps that follow extraction.

FULLY AUTOMATEDIVD
nRichDX Revolution Pro ES integrated automation system

Revolution Pro/ES

Integrated automation designed to minimize operator intervention from sample preparation through purified analyte.

  1. Revolution ProExtraction
  2. Revolution ESWash + elution
WorkflowFully automated processing with the Revolution ES accessory for wash and elution.
Revolution Elution Station (ES)

Revolution Elution Station (ES)

The ES accessory performs washing, drying, and final analyte elution after Revolution Pro processing. This configuration uses the ES Reagent Kit for those steps.

AutomationFully Automated
Designed ForSample preparation through purified analyte
HIGHLY AUTOMATEDResearch Use Only
nRichDX Revolution Pro + Hamilton STAR automation platform

Revolution Pro + Hamilton STAR

Scalable automation designed to support high-throughput batch processing.

  1. Revolution ProExtraction
  2. OperatorRack transfer
  3. Hamilton STARWash + elution
WorkflowAutomated extraction on Revolution Pro, followed by a manual rack transfer to Hamilton STAR for automated wash and elution.
Hamilton STAR automation platform

Hamilton STAR workflow

Hamilton STAR performs automated wash and elution after an operator transfers the rack from Revolution Pro. Reagent requirements depend on the Hamilton configuration.

AutomationHighly automated
Designed ForHigh-throughput batch processing
Revolution Plus
ALSO IN THE REVOLUTION FAMILY

Revolution Plus

Explore the semi-automated system and application-specific kits for your laboratory.

Explore Revolution Plus
NRICHDX + HAMILTON

A shared workflow.
Science you can examine.

Revolution Plus + Hamilton Microlab STAR.

Read the published application note on the Revolution Plus and Hamilton Microlab STAR workflow. Then discuss how the Revolution platform and Hamilton automation can fit your laboratory at Booth #915.

nRichDXHamilton
THE SENSITIVITY LADDER™

Find the sample input your assay actually needs.

Performance optimization, not volume maximization.

Evaluate how changes in input affect recovery and a defined assay endpoint. Identify where meaningful performance plateaus while considering specificity, background, reproducibility, sample quality, and workflow requirements.

Explore the Sensitivity Ladder™
Open video
Conceptual Sensitivity Ladder illustrating assay performance across increasing sample input volumes
Conceptual nRichDX framework; establish the appropriate input for the specific assay and workflow. Related analytical-validation research: 1 Deveson IW, et al. Nat Biotechnol. 2021;39:1115–1128. Read the publication.
  1. 01

    Evaluate

    Test multiple sample inputs.

  2. 02

    Measure

    Measure the defined assay endpoint at each input.

  3. 03

    Optimize

    Identify where meaningful performance begins to plateau.

  4. 04

    Standardize

    Select and define the workflow conditions.

  5. 05

    Automate

    Translate the selected workflow into repeatable execution.

AMP 2026 · BOOTH #915

Plan your visit to nRichDX in Seattle.

Explore Revolution Pro, compare automation options, and connect the presentation data to your sample-preparation questions.

nRichDX AMP booth rendering
NRICHDX AT AMP 2026Booth #915
AMP exhibit hall floorplan showing nRichDX Booth 915
Find Booth #915Enlarge map
EVENTNovember 10–14, 2026

AMP Annual Meeting & Expo

VENUESeattle Convention Center

Seattle, Washington

YOUR CONVERSATIONRecovery + workflow

Sample input, kits, and automation options

COUNTDOWN TO AMP 2026

November 10, 2026 · Seattle

–Days
–Hours
–Minutes
–Seconds
MEET WITH NRICHDX AT AMP

Let’s talk about your laboratory.

Meet with Kamran Syed or Nafiseh Jafari, PhD.

Tell us what you are developing or running today, your sample type and volume, and what you need to improve. We’ll help focus the conversation on the questions that matter to your program.

Booth #915 · Seattle Convention Center
During AMP, by appointment

Request your AMP meeting.

Send your preferred day and time, who you would like to meet, and a few details about your application.

Email a Meeting Request

Our team will follow up to confirm your meeting time.

REVOLUTION PRO LAUNCH · AMP 2026

Your next workflow conversation starts at Booth #915.

Explore the systems. Examine the science. Meet the team.